Loading...

  •      

Digital Display Product Selection Table


Use


CHTK series intelligent digital display meter is a multi-functional combination type instrument. It is suitable for the field monitoring and display of power grid and automation control system and remote control measurement of automation dispatching remote device. Its function is that CPU control medium AC sampling A/D analog converts the electrical parameters such as current, voltage, power, frequency, power factor and other values in the grid and then outputs a standard current or voltage signal, and connects with remote data terminal RTU. The RS-232 or RS-485 interface of the instrument can exchange data directly with the control center to realize automatic management. In addition, there are intelligent functions in this series of meters for non-electricity, variable transmission and alarm input and output of pressure, temperature, flow, etc.
At present, the series has been widely used in water conservancy, environmental protection, electric power, metallurgy, railroad and other industries.

Naming Meaning


Note: Multi-function meter with extended functions: harmonic content 2-31 times, multi-time multi-rate, variable output, switching input and output, alarm output. Other meters with extended functions: variable output, switching input and output, alarm output.

Function

It can replace the original analog digital display meter or pointer meter, and can measure, display and control the electric parameters such as current, voltage, power, frequency and power factor in the power grid and automation control system.

Features

Smart meter in the analog digital display meter of high precision, stable, reliable, no reading error, anti-vibration characteristics on the basis of increased, cost-effective, zero and full degree software adjustable accuracy, variable ratio can be set, automatic control, communication and other characteristics. Among them, the zero point and full degree software adjustable accuracy, variable ratio can be set more conducive to the majority of customers' stocking.

General indicators

Technical parameters

Indicators

Accuracy grade

Display accuracy: 0.5, 0.2 level, transmission accuracy: 0.5, 0.2 level

Display digits

4-bit, plus symbol bit LED display

Input

Nominal Input

Current AC1, AC5A, DC20mA, etc., AC10V, AC220V, AC380V, DC75mV, etc.

Over-range

Continuous: 1.2 times, instantaneous: 10 times current (5 seconds), 2 times voltage (1 second)

Power supply

Auxiliary power

AC/DC80~270V;AC220V¡À10%

Power consumption

¡Ü4VA

Industrial frequency withstand voltage

Power supply and input, transmission output, communication interface for AC2KV (test voltage for AC rms) input, transmission output, communication interface between two two for AC1KV (test voltage for AC rms)

Insulation resistance

¡Ý100M¦¸

Average trouble-free operating time

¡Ý50000h

Normal working conditions

Ambient temperature:-40~50¡æRelative humidity¡Ü90%,no corrosive gas place,altitude¡Ü2500mDC4~20mA current output load<600¦¸D,C0~5V voltage output load>10K¦¸



Digital display electric measuring instrument shape and opening size



Model

External designation

Outer frame overall dimension

Screen mount fit size

Opening size

Minimum installation distance

Total length

Remarks

a

b

16 Slotted

1

160¡Á80

150¡Á70

151¡Á71

180

100

80

-

42 square

2

120¡Á120

110¡Á10

111¡Á111

140

140

80

-

6 Square

3

80¡Á80

75¡Á75

76¡Á76

100

100

75

-

46 Slotted

4

120¡Á60

115¡Á5

116¡Á56

140

80

80

-

Micro-groove shape

5

96¡Á48

90¡Á4

91¡Á45

116

68

112

-

96 square

9

96¡Á96

90¡Á90

91¡Á91

116

116

75

-

61 square

A

72¡Á72

66¡Á6

67¡Á67

92

92

75

-

Micro Square

D

48¡Á48

44.5¡Á4.5

45¡Á45

68

68

85

-



Application examples



Cabinet type

Specification Model

Face frame size

Function Description

Remarks

Inlet cabinet

CHTK900E-2FY

120X120

All power parameters in the power network£º

Three-phase voltage, three-phase current, 

active power, reactive power, power factor,

 frequency, four-quadrant electrical energy, 

LCD display, time-of-day multi-rate metering.

Switching, variable output,

communication optional


CHTK900E-9FY


96X96

CHTK900E-2S4

120X120

All power parameters in the power network£º

Three-phase voltage, three-phase current, 

active power, reactive power, power factor,

 frequency, four-quadrant power

CHTK900E-9S4

96X96

CHTK900E-9HY

96X96

Harmonic measurement, multi-rate, grid quality analysis

Outlet fixed cabinet (GGD)

CHTK900I-2¡õ1




120X120

Single-phase current

Switching, 

variable output communication,

alarm optional

CHTK900I-2¡õ4

Three-phase current

CHTK900U-2¡õ1

Single-phase voltage

CHTK900U-2¡õ4

Three-phase voltage

CHTK900UI-2¡õ1

Single-phase voltage and current combinations

CHTK900UI-2¡õ4

Three-phase voltage and current combination

CHTK900I-9¡õ1




96X96

Single-phase current

CHTK900I-9¡õ4

Three-phase current

CHTK900U-9¡õ1

Single-phase voltage

CHTK900U-9¡õ4

Three-phase voltage

CHTK900UI-9¡õ1

Single-phase voltage and current combinations

CHTK900UI-9¡õ4

Three-phase voltage and current combination

CHTK900I-3¡õ1




80X80

Single-phase current

CHTK900I-3¡õ4

Three-phase current

CHTK900U-3¡õ1

Single-phase voltage

CHTK900U-3¡õ4

Three-phase voltage

CHTK900UI-3¡õ1

Single-phase voltage and current combinations

CHTK900UI-3¡õ4

Three-phase voltage and current combination

Outlet drawer cabinet (GCK) (MNS), etc.

CHTK900I-D¡õ1

48X48

Single-phase current

Switching,

variable output communication,

alarm optional

CHTK900I-A¡õ1

72X72

Single-phase current

CHTK900I-3¡õ1

80X80

Single-phase current

CHTK900U-D¡õ1

48X48

Single-phase voltage

CHTK900U-A¡õ1

72X72

Single-phase voltage

CHTK900U-3¡õ1

80X80

Single-phase voltage

Outlet drawer cabinet (GCK, MNS), etc.

CHTK900I-D¡õ4

48X48

Three-phase current

Switching output,

communication, 

alarm optional

CHTK900I-A¡õ4

72X72

Three-phase current

CHTK900I-3¡õ4

80X80

Three-phase current

CHTK900U-D¡õ4

48X48

Three-phase voltage

CHTK900U-A¡õ4

72X72

Three-phase voltage

CHTK900UI-3¡õ4

80X80

Three-phase current-voltage combination

Outlet metering cabinet

CHTK900E-9SY



96X96

LCD display, all power parameters

Switching, 

variable output, 

communication optional

CHTK900E-9S4

Digital display, all power parameters

CHTK900E-9S9

Three-phase current and electrical energy

CHTK900E-9S7

Four-quadrant electrical energy

Power distribution and metering cabinet

CHTK900W-9S1

96X96

Single-phase electrical energy metering

CHTK900W-9S4

Three-phase electrical energy metering

Reactive power compensation cabinet

CHTK900E-9S5



96X96



120X120

U, I, P, Q, etc. switch display, digital display

Switching, 

variable output,

communication optional

CHTK900E-9S5Y

U, I, P, Q, etc. switch display, LCD display

CHTK900H-9K1

Power Factor measurement with optional switching input.

Switching output

CHTK900H-2C1

Power Factor Compensation Control

Contact Cabinet

CHTK900E-9S5

96X96

U, I, P, Q, etc. switch display, digital display

CHTK900E-9S5Y

U, I, P, Q, etc. switch display, LCD display





Online Message

*
*
*

Related Products

See More