Active and Reactive Frequency Table (Design Paragraph)


Overview

This series of intelligent digital display power meter is a high-precision meter developed for power measurement and display in power grid and automatic control system. It has the advantages of intuitive display, high precision, good stability and strong vibration resistance. CPU digital processing, AC true RMS measurement, CT (PT) can be set through the panel keys. Optional: 1 relay control output, can be set to: upper limit; lower limit; upper and lower limit, 2 digital output, RS485 communication interface, using standard Modbus-RTU protocol, can be directly connected with industrial configuration software, easy to group network, 3. All the way analog output.


Operating Instructions


1. key definition
Function key SET: It is used to enter the menu, and it is the confirmation key in programming mode.
Shift key: Cycle through the nixie tubes in the selected page, and the selected nixie tubes are flashing.
Increase key ¡ø: Enter the setting value, change the value of the flashing digital tube (the numbers cycle from 0 to 9).

2. Operation method
Use the menu key SET to select the setting page, use the increase key ¡ø to enter the setting value setting, use the shift key and the increase key ¡ø to change the digital tube value on the page, adjust to the desired value and press the function key SET to confirm and exit the programming state.

Features

1. Single-phase and three-phase can be set through the panel buttons
2. Display range: C0.000¡«1.000¡«L0.000
3. Software adjustment, no internal potentiometer, high precision
4. Optional with communication function. (must be specified when ordering)
5. Optional with upper and lower limit alarm control function

Instructions

1. Press and hold the SET button for 6 seconds to enter the menu, the r-H (for setting direct reading parameters) mark appears, and then press SET again to enter the set value (0005), this value is the displayed value (ie the base value), this You can use the up key ¡°¡÷¡± to change the large value, and you can also use the down key ¡°¨Œ¡± to change the small value. Press the SET key again to display the r-K (set magnification) mark, and press SET again to enter the set value (0001). At this time, you can use the up key ¡°¡÷¡± to change the large value, and you can also use the down key ¡°¨Œ¡± to change the small value.
Note: If it is a simple function, after completing the operation through the above keys, press the SET key continuously to exit.

2. If you want additional functions, you can continue to complete the operation through the following keys:
Press the SET key again to display the Addr (communication address) sign, and press SET again to enter the set value (0001). At this time, you can use the up key ¡°¡÷¡± to change the large value, or use the down key ¡°¨Œ¡± to change the decimal value. Press the SET key again to display the BAUD (baud rate) mark, and press SET again to enter the set value (9600). At this time, you can use the up key ¡°¡÷¡± to change the large value, or use the down key ¡°¨Œ¡± to change the decimal value . Press the SET button again to display the ALHL (alarm) sign, press SET again to enter the upper limit alarm setting (AH-Y), if you want to set the lower limit alarm, you can press the up button ¡°¡÷¡± again to enter the lower limit alarm setting (AL-Y) ), then press SET to display the (ALN) sign, then press SET again to enter the alarm value setting menu (2000). At this time, you can use the up key ¡°¡÷¡± to change the larger value, or press the down key ¡°¨Œ¡± Change the decimal value.

Matters Needing Attention

1. Before use, the meter needs to be powered on for 15 minutes.
2. Pay attention to prevent vibration and impact, and do not use it in places with excess dust and excess harmful gases.
3. The input wire should not be too long. If the input end of the signal under test is long, please use a twisted pair shielded wire.
4. If the signal is accompanied by high frequency interference, a low frequency filter should be used in the line.
5. When not in use for a long time, please turn on the power for no less than 4 hours every three months.
6. Long-term storage should avoid direct light, and should be stored at -10¡æ~70¡æ.
7. If there is no display on the meter, first check the auxiliary power supply to see if the voltage is within the specified range.
8. If the display is abnormal, check whether the input signal is normal and whether the signal terminals are tightened.
9. Unless the PT has enough power, the PT signal cannot be used as an auxiliary power supply at the same time to ensure the normal operation of the instrument.
10. The screws of the current terminals in the CT circuit must be tightened to ensure reliable contact between the incoming and outgoing wires to avoid malfunctions.
11. To calibrate the instrument, the calibration instrument should be better than level 0.1 to ensure the calibration accuracy.

Product In Kind


External Dimensions


Product selection

product name

product model

basic function

remarks

Three-phase active power meter

CHTK900P-2Kl

Three-phase active power

A row of LED digital tubes shows the display

True effective value measurement, the whole four-digit display

Optional band with communication function, optional band

The analog volume outputs either DC4-20mA or

0-20mA, Alarm output.

Protable table arbitrary through panel buttons

Adjust the display value 1~9999, software

Adjustment, high precision, long-term work without adjustment.

Open hole is 111mm * 111mm

CHTK900P-9Kl

Open hole is 91mm * 91mm

CHTK900P-1Kl

Open hole is 152mm * 76mm

CHTK900P-4Kl

Open hole is 115mm * 56mm

CHTK900P-5Kl

Open hole is 91mm * 45mm

 

 

 

 

three phase varmeter

CHTK900Q-2Kl

Three-phase reactive power

A row of LED digital tubes shows the display

True effective value measurement, the whole four-digit display

Optional band with communication function, optional band

The analog volume outputs either DC4-20mA or

0-20mA, Alarm output.

Protable table arbitrary through panel buttons

Adjust the display value 1~9999, software

Adjustment, high precision, long-term work without adjustment.

Open hole is 111mm * 111mm

CHTK900Q-9Kl

Open hole is 91mm * 91mm

CHTK900Q-1Kl

Open hole is 152mm * 76mm

CHTK900Q-4Kl

Open hole is 115mm * 56mm

CHTK900Q-5Kl

Open hole is 91mm * 45mm

product name

Product model

basic function

remarks

Single-type three-phase power factor table

CHTK900H-2Kl

A row of LE D digital tubes is on display

Single and three-phase phases can be set through the panel buttons

Display range: C0.000~1.000~LO.000

Software tuning, internal no potentiometer, high accuracy is optional with communication function.(Should be indicated when ordering) with optional upper and lower limit alarm control function

Open hole is 111mm * 111mm

CHTK900H-9Kl

Open hole is 91mm * 91mm

CHTK900H-3Kl

Open hole is 76mm * 76mm

CHTK900H-AK1

Open hole is 68mm * 68mm

CHTK900H-5Kl

Open hole is 91mm * 45mm

CHTK900H-1Kl

Open hole is 151mm * 71mm

CHTK900H-4Kl

Open hole is 115mm * 56mm

Frequency Table CHTK900F

tachometer CHTK900N

Pressure gauge: CHTK900N

Weight gauge: CHTK900N

Special table et al. CHTK900N

CHTK900F(N)-2Kl

A row of LED digital tubes shows that,

Various input signals,

For example, there are: DC4-20MA,

DC0-20MA,DC10V,DC75MV

So on programmable through the panel button

Any adjustment display value 1~9999,

The whole four-display, optional belt up and down

Limited alarm control function, optional with variable transmission

Output, optional with communication function.

Open hole is 111mm * 111mm

CHTK900F(N)-9Kl

Open hole is 91mm * 91mm

CHTK900F(N)-3Kl

Open hole is 76mm * 76mm

CHTK900F(N)-AK1

Open hole is 68mm * 68mm

CHTK900F(N)-5Kl

Open hole is 91mm * 45mm

CHTK900F(N)-1Kl

Open hole is 151mm * 71mm

CHTK900F(N)-4Kl

Open hole is 115mm * 56mm

CHTK900F(N)-DK1

Open hole is 45mm * 45mm