Loading...

Capacitive transmitter


Overview


DWP-3051/1151 series capacitive transmitters can be widely used in metallurgy, oil refining, power petrochemical, medicine, paper making, environmental protection food and textile and other industrial sectors to measure the differential pressure, pressure and liquid pressure of liquid, gas and steam. Bit, density, and other parameters can also be used for measurement when matched with a throttle orifice. It converts the measured signal into a 4-20mADC, and combines it with other instruments to form an automatic detection, recording, calculation, adjustment or control instrument, which can form a variety of instruments. Industrial automatic control system.
This catalog gives a general introduction to the common characteristics of 3051/1151 series capacitive transmitters, including product model name, product series, main features, working principle, function parameters, etc. For more detailed information, please refer to the various Instruction manual for model transmitter.

Model Name



Product Specification


Main Features

¡ôComplete variety, high precision, good stability, cheaper price than similar imported instruments;
¡ôSpan and zero position can be continuously adjusted externally;
¡ôPositive migration up to 500%, negative migration up to 600% (minimum range);
¡ôAdjustable damping;
It can be seen from Table 1 that the 3051/1151 series capacitive transmitters produced by our company are complete in variety, and users can choose them arbitrarily according to different needs. In addition to 361L stainless steel, the wetted material also has Hastelloy C, Monel, SIOCFLON coating, etc., which can be used to measure corrosive media.
The 3051-1151 series transmitters are compact in design, easy to install, use and adjust. The electrical enclosure adopts a two-cavity structure, that is, the terminal block and the amplifier circuit each occupy a cavity. The airtightness is good, and it has an explosion-proof and all-weather structure. The amplifier circuit has reverse polarity protection to prevent damage to the transmitter due to wrong connection of power supply polarity. Since the volume change of the transmitter is less than 0.16cm3 when it is working, there is no need to add a condenser or liquid level cylinder to compensate for the volume change.
The 3051/1151 series transmitters produced by our company can be equipped with a 0~100% linear indicator for on-site output indication; they can also be equipped with a digital display for on-site output display. The display is 31/2 times LCD or LED display, and the reading accuracy ¡À 0.5% + 1 word, because the A/D converter, amplifier, liquid crystal, etc. of the display all use high-quality devices, so it is accurate, durable and reliable. Users can choose according to their own habits.

Working Principle

The two pressures of the measured medium enter the high and low pressure chambers, act on the two isolation diaphragms of the 6-element (ie, the sensitive element), and transmit to the pre-tensioned measuring membrane through the isolation diaphragm and the filling liquid in the 6-element both sides of the slice. The measuring diaphragm and the electrodes on the insulators on both sides form a capacitor respectively. When there is no pressure or the pressure on both sides is equal, the measuring diaphragm is in the middle position, and the capacitances of the two capacitors on both sides are equal. When the pressure on both sides is not consistent, the measuring diaphragm is displaced, and the displacement is proportional to the pressure difference, so the capacitance on both sides is not equal. By detecting the differential capacitance on the capacitor plate, the differential capacitance is detected by the electronic circuit. The capacitance is converted and amplified into a two-wire current signal of 4-20mADC. The working principle of pressure transmitter and absolute pressure transmitter is the same as that of differential pressure transmitter, the difference is that the pressure of the low pressure chamber is atmospheric pressure or vacuum.


Range code

1¡¢2¡¢3¡¢4¡¢5

6

7

8

9

0

M

54

55.2

55.6

57.2

59

60.6


Overview


The installation flange standard of 3051/1151TL capacitive liquid level transmitter is ANSI 2", 3", 4", and the flange level is 150lb and 300lb. The flange installation size is shown in the chart below. Standard, DN=80, 100, PN=2Mpa. The material of the liquid diaphragm includes 316L, Hastelloy C-276, Monel, silver, etc. The company can also provide users with other special specification installation flanges. Users do not pay attention Tomorrow, our company will supply with 3"150lb (2.5Mpa) installation flange.



D, D1, n, d, A, B, C dimensions in the above figure

Flange size mm

Bolt hole

Standard flange size

Outer diameter D

Thickness A

B

C

Number n

diameter d(mm)

Distribution diameter D1(mm)

2"

152

23

60

98

4

19

120

3"

190

24

66

127

4

19

152

4"

229

24

89

157

8

19

191


Product Selection Table


Model code

Function Description

DWP-3051/1151LT

Flange type liquid level transmitter (maximum working pressure 2.5MPa; special 4MPa¡ªplease specify when ordering)

Measuring range

4

  0-6.2~37.4 kPa

5

  0-31.1~186.8

6

  0-117~690

Output

E 4-20mADC common type, adjustable damping
S 4-20mADC intelligent type with HART protocol

Connection form (or category)

  Flat flange EO(2"), A0 (3"), B0(4")

2¡ä¡ä

Access flange: E2, E4, E6, (the length of the insertion tube is 50, 100, 150mn respectively)

3¡ä¡ä

Plug-in flange: A2, A4, A6, (insert lengths are 50, 100, 150mm respectively)

4¡ä¡ä

Plug-in flange: B2, B4, B6, (insert lengths are 50, 100, 150mn respectively)

Structural materials

 

Low pressure side pressure chamber and liquid contact diaphragm

High pressure side liquid isolation diaphragm

22

316

316L

23

316

Hastelloy C

24

316

Monel

25

316

Tantalum

33

Hastelloy C

Hastelloy C

35

Hastelloy C and Tantalum

Tantalum

44

Monel

Monel

Additional features

 

M1

0-100% linear indicator

M3

3 1/2LCD digital display

M4

3 1/2 LED digital display

M5

4-digit LCD or LED digital display

B1

Pipe bend bracket

B2

Board Mount Bend Bracket

B3

Tube Mounted Flat Bracket

D1

Side relief valve on the upper part of the pressure chamber

D2

Side relief valve in the lower part of the pressure chamber

N

Low pressure side 1/2-14NPT tapered pipe female twisted joint

J

Low-pressure side M20¡Á1.5 T-shaped male thread sand connection

d

dllBT4

i

Intrinsically safe iallCT6

DWP-1151LT5EA622M3B1 ---Type selection example


Overview


The 3051/1151DP¡€GP transmitter becomes a remote differential pressure or pressure transmitter after being equipped with a remote sealing device. The remote transmitter can avoid direct contact between the measured medium and the diaphragm of the transmitter.


Applicable Environment

1. The measured medium has a corrosive effect on the transmitter joint and sensitive components;
2. It is necessary to isolate the high-temperature measured medium from the transmitter;
3. There are solid suspended matter or high viscosity in the measured medium, which is easy to block the transmitter joint and pressure chamber;
4. Hygienic conditions must be protected to prevent contamination.

Measuring Range: 0~6kPa-0~10Mpa


A variety of structural materials are provided, and the welding structure of the components of the remote transmission device is highly reliable. The low-volume design of the liquid-filled cavity reduces the impact of temperature. According to user requirements, the operating temperature range of ordinary silicone oil is -40+149¡ãC; the operating temperature range of high-temperature silicone oil is 15-315¡ãC, see Table 23 for details.
The upper limit of the working pressure of the remote transmission device is the rated value of the remote transmission device selected by the user; the working pressure shall not be lower than 3.5kPa (absolute pressure). For corrosive media, please refer to Table 25 for the material selection of the isolation diaphragm (only for reference when selecting by the user).



Model code

Function Description

3051/1151DP -GP

Remote differential pressure, pressure transmitter

Measuring range

4

   

5

   

6

   

7

   

8

   

Output

E  
S  

Flange material

 

Flange material

Isolation diaphragm

12

Carbon steel nickel plated

316L stainless steel

22

316 stainless steel

316L stainless steel

Isolation diaphragm

 

s1

One remote devices

According to Table 16~21 to place an order

s2

Two remote devices

Additional features

 

M1

0~100% linear indicator

M3

3 1/2LCD digital display

M4

3 1/2 LED digital display

M5

4-digit LCD or LED digital display

B1

Pipe bend bracket

B2

Board mount bracket

B3

Tube Mounted Flat Bracket

d

Flameproof dllBT4

i

Intrinsically safe iall CT6

DWP-1191RFW21A11A21-30 ---Selection example


Product selection


product name

product model

basic function

remarks

Capacacitive differential voltage transmitter

TKWP-3051 Series

Measurement range: -100KPa-40MPa Measurement accuracy: 0.2% 0.5% 0.075%

Working power supply: DC12-36V

Output signal: 4-20mA 0-10V 0-5V 1-5V

Stainless steel belt base

Online Message

*
*
*

Related Products

See More