Loading...

Single-phase rail energy meter



Safety Guidance


Information about your personal safety
Due to different conditions or requirements, this manual cannot cover all the safety matters related to the operation of this instrument, but it is very important to understand the following items to ensure your personal safety and prevent damage to the instrument. These items are highlighted with a triangular safety symbol, depending on the degree of potential hazard indicated.

Environmental Indicators

Working Humidity  ¡Ü 75%
Storage Humidity  ¡Ü 95%
Operating Temperature  -10¡ãC - +50¡ãC
Storage Temperature  -30¡ãC - +70¡ãC
International standardIEC  62053-21
Domestic Standard  GB/T17215.321-2008
Accuracy Class  1
Dustproof and Waterproof  IP 51
Protective Insulation Encapsulation Type  ¢ò

Technical Parameters And Display Type

Model (LCDDisplay)
Reference Voltage (Un) 220V    230V    240V
Operating Voltage 181/279V AC (3~)
Rated Current (Ib)   2.5   5A  10A  15A  20A   30A
Maximum Current (Imax) 10A  20A  40A  60A  80A   100A
Starting Current ¡Ü0.004b£¨Direct Access£©
Withstand Overload Current 30Imax    0.01s
Working Frequency   50Hz¡À10%
Internal Power Consumption ¡Ü2W / 10VA
Pulse Constant 1000imp
RS485 Port  23(A)and24(B)
Data Storage Time >20 Years

LCD Display

1st Screen displays ID address                  Add         001
2nd Screen displays baud rate                   bd          9600
3rd Screen displays constant                    CoSE        1000imp

The fourth screen keeps displaying

4thScreen displays the total amount of electricity   000000.00   kWh

Intrinsic Error

Single phase balanced load

0.05Ib             Cos¦Õ = 1        ¡À1.5%
0.1Ib              Cos¦Õ = 0.5L     ¡À1.5%
Cos¦Õ = 0.8C     ¡À1.5%
0.1Ib - Imax        Cos¦Õ = 1        ¡À1.0%
0.2Ib - Imax        Cos¦Õ = 0.5L     ¡À1.0%
Cos¦Õ = 0.8C     ¡À1.0%




Outline And Structure

A: Front panel

B: Cover

C:Bottom

D: Seal

Front panel       Flame-retardant PC

Cover            Flame-retardant ABS or PC

Bottom           Flame-retardant ABS or PC

Dimension        89.9mmx35mmX72mm

Weight            0.12 Kg (Net Weight)

Terminal

Notice

1/3

Input/output

4/5

RS485 port

6/7

Pulse output

8/9

Neutral line



Product selection



product name

product model

basic function

remarks

Single-phase electricity meter

CHTK13521-1

Single P level

Direct and accurate measurement of active power rated at 50H Z or 60H Z 1.5 (6) A, 5 (20) A, 5 (25) A, 5 (30) A, 5 (32) A, 40 (100)

Accuracy is level 0.5

Total electrical power is displayed by a 6 + 1-bit LCD

Length * in width * 90mm * 18mm * 66mm in height

CHTK13521-2

Class 2P

Length * width * height 75mm * 18mm * 55mm respectively

CHTK13521-4

Level 4P

Length * width * height of 91mm * 76mm * 74mm respectively


Online Message

*
*
*

Related Products