Loading...
Precision | ㊣05%F﹞S |
Insulation strength |
Between input, output and power supply, AC1500V/1 minute |
linear | ㊣0.1 %F﹞S |
Insulation resistance |
Between input, output and power supply, 100M次 (DC500V) |
Load Resistance | 250~750次 |
Consumption of utility |
1.5W (one way) |
Temperature Coefficient | <100ppm/⊥ |
Power supply |
DC24V㊣10% |
Response time | <0.1S (0-9%) |
Operating temperature |
0-40⊥ <95%RH |
Name |
Input signal |
Output signal | Function |
Distributor (single channel) |
4~20mADC |
4~20mADC or 1~5VDC |
It provides distribution power to the two-wire transmitter and converts the signal isolation of the transmitter to the output |
Distributor (dual channel) |
4~20mADC |
4~20mADC or 1~5VDC | |
Distributor (one into two out) |
4~20mADC |
4~20mADC or 1~5VDC | |
Distributor/Isolator |
4~20mADC |
4~20mADC or 1~5VDC | |
Isolator (single channel) |
4~20mADC |
4~20mADC or 1~5VDC |
nput and output signal isolation conversion |
Isolator (dual channel) |
4~20mADC |
4~20mADC or 1~5VDC | |
Isolator (one in two out) |
4~20mADC |
4~20mADC or 1~5VDC | |
Isolator (single channel) |
1~5VDC |
4~20mADC or 1~5VDC | |
Isolator (dual channel) |
1~5VDC |
4~20mADC or 1~5VDC | |
Thermocouple Transmitter |
Thermocouple (single input) |
4~20mADC or 1~5VDC (dual isolated output) |
Converts the transmitter*s temperature signal isolation to an output |
Thermal resistance transmitter |
Thermal resistance (single input) |
4~20mADC or 1~5VDC (dual isolated output) |
product name |
product model |
basic function |
remarks |
|
DC current separator |
CHTK1522 |
Input all DC flow, output all DC small signal, power DC24 power supply |
Length: * width: * height: 108mm*25.4mm: * 47mm |
|
AC voltage isolator |
CHTK1520 |
Input all AC voltage, output small DC signal, power supply DC24 |
||
DC voltage separator |
CHTK1521 |
Input all DC voltage, output small DC signal, power supply DC24 |
||
Second-line isolation device |
CHTK1525 |
Input a second line system, output a road DC signal, Power supply DC24 power supply |
||
AC current separator |
CHTK1526 |
Input all AC current, output small DC signal, power supply DC24 |
||
(passive) passive isolator |
CHTK1562 |
Input one DC signal and output one DC signal |
||
potentiometer signal isolator |
CHTK9020 |
Input a road potentiometer, output a road DC signal, power supply DC24 power supply |
||
Thermal resistance isolator |
CHTK9050 |
Input thermal resistance, output DC signal, power DC24 power |
||
Thermocouple isolator |
CHTK9060 |
Input a thermocouple, output a DC signal, power supply DC24 power supply |
||
Resistance signal isolator |
CHTK2020 |
Input one road resistance or potentiometer signal, output one road DC small signal, power supply DC24V |
||
product name |
product model |
basic function |
remarks |
|
Super Pu-type signal isolator |
CHTK1622 |
Input one road DC signal, output one road DC signal, power supply AC / DC220 or DC24V |
Length * width * height 106mm*12.5mm * 112mm |
|
Super Pu type thermal power resistance separator |
CHTK169050 |
Input one road thermal resistance signal, output one road DC signal, power supply AC / DC220 or DC24V |
||
Super Pu type thermocouple separator |
CHTK169060 |
Input one road thermocouple signal, output one road DC signal, power supply AC / DC220 or DC24V |
||
Safety gate signal separator |
CHTK1822 |
Input a DC signal, output a DC signal, power DC24V, detection input and operation output |
Length, * width, * height, 122mm * 18mm * 96mm |
|
Thermoelectric resistance safety gate |
CHTK189050 |
Input one road thermal resistance signal, output one road DC signal, power supply DC24V |
||
Thermocouple safety gate |
CHTK189060 |
Input one road thermocouple signal, output one road DC signal, power supply AC / DC220 or DC24V |
||
Pluggable signal isolator |
CHTK1722 |
The full signal isolator inputs one DC signal, output DC signal, power supply AC / DC220 or DC24V |
Length, * width, * height, 85mm * 23mm * 103mm |
|
Plug-in thermal resistance isolator |
CHTK179050 |
The full signal isolator inputs one thermal resistance signal, one DC signal, power supply AC / DC220 or DC24V |
||
Plug-in thermal resistance isolator |
CHTK179060 |
The full signal isolator inputs one-way thermocouple signals and outputs one-way DC signal power supply AC / DC220 or DC24V |
||
Full signal isolator |
CHTK15241 |
Input one road DC signal, output one road DC signal, power supply AC / DC220 or DC24V |
Length * in width * 99mm * 35mm * 115mm in height |
|
Full signal isolator |
CHTK15242 |
Input one DC signal and output two DC signals, power supply AC / DC220 or DC24V |
||
Full signal isolator |
CHTK15244 |
Input one-way DC signal, output four-way DC signals, power supply AC / DC220 or DC24V |
||
Full signal isolator |
CHTK15252 |
Input one second line system, output two DC signals, power supply AC / DC220 or DC24V |
||
(passive) passive isolator |
CHTK15622 |
Input a primary DC signal, Output the two-way DC signals |
||
DC isolator |
CHTK21522 |
Input two DC currents, output two small DC small signals, power supply AC / DC220 or DC24V |
||
Second-line isolation device |
CHTK21525 |
Input two two lines, output two DC signals, power AC / DC220 or DC24V |
||
Thermal resistance isolator |
CHTK90501 |
Input one thermal resistance, output one DC signal, power supply AC / DC220 or DC24V |
||
Thermal resistance isolator |
CHTK90502 |
Input one thermal resistance, output two DC signals, power supply AC / DC220 or DC24V |
||
Thermocouple isolator |
CHTK90601 |
Input one road thermocouple, output one road DC signal, power supply AC / DC220 or DC24V |
||
Thermocouple isolator |
CHTK90602 |
Input one thermocouple, output two DC signals, power supply AC / DC220 or DC24V |
||
Thermocouple temperature transmitter |
SBWR |
Integrated module temperature transmitter Basic error soil 0.2%, 0.5%, environmental temperature change, 0.20.02%FS /⊥, 0.50.05FS /⊥, output signal: 4~20mA, second line transmission; load resistance: 0~600 power supply: 12~36VDC; working environment |
朴 45mm*15mm |
|
Thermal resistance temperature transmitter |
SBWZ |